Part Number Hot Search : 
29LV0 DW1T1 74HC366 CA3080AX MC1741 SFH934 WJ120 RF2498
Product Description
Full Text Search
 

To Download DMC-50747NF-AK Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 First Edit ion
Jul 9, 2001
O PTREX
LCD Module Technical Specification Final Revision
******
Type No.
DMC-50747NF-AK
Approved Div.) ) Checked Div.) Checked by (Design Engineering Div.) ) Prepared by (Product ion Div.) by (Qualit y Assurance by (Product ion
Table of Contents
1. General Specificat ions.....................................................................................................................................................2 2. Elect rical Specificat ions.................................................................................................................................................3 3. Opt ical Specificat ions......................................................................................................................................................7 4. I/ O Terminal............................................................................................................................................................................9 5. Test ..............................................................................................................................................................................................11 6. Appearance St andards..................................................................................................................................................12 7. Code Syst em of Product ion Lot ............................................................................................................................15 8. Applying Precaut ions......................................................................................................................................................15 9. Precaut ions Relat ing Product Handling............................................................................................................16 10 . Warrant y ................................................................................................................................................................................17
Revision History
Rev. Dat e Page Comment
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 1/ 17
1. Gener al Spec if ic at ions
Operat ing Temp. St orage Temp. Display Format Display Font s Viewing Area
: : : : :
min. 0C ~ max. 50C min. - 20C ~ max. 70C 16 charact ers *~2 lines 5 *~7 dots ( 1 charact er ) 60.2 (W) *~16.6 (H) mm 64.2 (W) *~27.6 (H) *~2.2 max. (D) mm * Wit hout FPC 10g max. NRD- 17533 ( F- STN / Black &Whit e- mode / Reflect ive ) 6:00 8- bit parallel dat a t ransfer None I/ O FPC Type Dimensional Out line UE- 310783
Out line Dimensions :
Weight LCD Type
: :
Viewing Angle Dat a Transfer Backlight Addit ional Spec. Drawings
: : : : :
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 2/ 17
2.Elec t r ic al Spec if ic at ions
2.1.Absolut e Maximum Rat ings VSS=0V Paramet er Supply Volt age (Logic) Supply Volt age (LCD Drive) Input Volt age VI - 0.3 VDD+0.3 V VDD- VOUT V5=VOUT - 0.3 16.0 V Symbol VDD- VSS Condit ions Min. - 0.3 Max. 6.0 Unit s V
2.2.DC Charact erist ics Ta=25C, VSS=0V Paramet er Supply Volt age (Logic) Supply Volt age (LCD Drive) High Level Input Volt age Low Level Input Volt age Supply Current IDD VDD- VSS=3.0V 0.05 0.1 mA VIL VDD=3.0V10% 0 0.2VDD V VIH VDD=3.0V10% 0.8VDD VDD V VDD- VOUT Shown in 3.1 V Symbol VDD- VSS Condit ions Min. 2.4 Typ. 3.0 Max. 3.6 Unit s V
Note.1 Note.1 : Triple boost ing st at e and checker pat t ern.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 3/ 17
2.3.AC Charact erist ics 2.3.1.Syst em Bus Writ e Charact erist ics 1 (80 series MPU) VDD=3.0V10% Paramet er Syst em Cycle Time Address Set up Time Address Hold Time Dat a Set up Time Dat a Hold Time Symbol Min. 500 60 30 100 50 Max. Unit s ns ns ns ns ns
Cont rol Pulse Width 100 ns Note 1 : For t he rise and fall of an input signal, set a value not exceeding 25ns. Note 2 : Every t iming is specified on t he basis of 20%and 80%of VDD.
tAH
A0, CS
t CYC t AW t AH t DS t DH t CC
tAW tCC
WR
tCYC
tDS
D0~D7
tDH
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 4/ 17
2.3.2.Syst em Bus Writ e Charact erist ics 2 (68 series MPU) VDD=3.0V10% Paramet er Syst em Cycle Time Address Set up Time Address Hold Time Dat a Set up Time Dat a Hold Time Symbol Min. 500 60 30 100 50 Max. Unit s ns ns ns ns ns
Cont rol Pulse Width 100 ns Note 1 : For t he rise and fall of an input signal, set a value not exceeding 25ns. Note 2 : Every t iming is specified on t he basis of 20%and 80%of VDD.
t CYC t AW t AH t DS t DH t CC
tCYC
E
tAW
A0, CS
tEW
tAH
tDS
D0~D7
tDH
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 5/ 17
2.3.3.Reset Timing VDD=3.0V10% Paramet er Reset Time Reset Pulse Width Symbol Condit ions Note 1 Note 2 Min. 1.0 10 Max. Unit s
ms ms
Reset St art Time Note 2 50 ns Note 1 : t R ( Reset Time ) indicat es t he internal circuit reset completion t ime from t he edge of t he RES signal. Accordingly, it usually ent ers t he operat ing st at e aft er t R. Note 2 : Specifies t he minimum pulse width of t he RES signal. It is reset when a signal having t he pulse width great er t han t RW is ent ered.
VDD Power Supply VSS
tR t RW t RES
tRES
VDD RES VSS
tRW
tR
All signal timings are based on 20% and 80% of VDD signals.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 6/ 17
3.Opt ic al Spec if ic at ions
3.1.LCD Driving Volt age Paramet er Recommended LCD Driving Volt age VDD- VOUT Symbol Condit ions Ta= 0C Ta=25C Min. 6.2 Typ. 6.5 Max. 7.3 6.8 Unit s V V
Note 1 Ta=50C 5.7 V Note 1 : Volt age (Applied act ual waveform t o LCD Module) for t he best cont rast . The range of minimum and maximum shows t olerance of t he operat ing volt age. The specified cont rast rat io and response t ime are not guarant eed over t he ent ire range.
3.2.Opt ical Charact erist ics Ta=25C, 1/ 16 Dut y, 1/ 5 Bias, VD=6.5V (Note 4), q= 0, f= - Paramet er Cont rast Rat io Viewing Angle Response Rise Note 2 TON Note 1 Symbol CR Condit ions
q= 0, f= -
Min. -
Typ. 7
Max. -
Unit s
Shown in 3.3 50 100 ms
Time Decay Note TOFF 85 170 ms Note 1 : 3 Cont rast rat io is definded as follows. CR = LOFF / LON LON : Luminance of t he ON segment s LOFF : Luminance of t he OFF segment s Note 2 : The t ime t hat t he luminance level reaches 90%of t he sat urat ion level from 0%when ON signal is applied. Note 3 : The t ime t hat t he luminance level reaches 10%of t he sat urat ion level from 100%when OFF signal is applied. Note 4 : Definit ion of Driving Volt age VD Assuming t hat t he t ypical driving waveforms shown below are applied t o t he LCD Panel at 1/ A Dut y - 1/ B Bias ( A : Dut y Number, B : Bias Number ). Driving volt age VD is definded as follows. VD = (Vt h1+Vt h2) / 2 Vt h1 :The volt age VO- P t hat should provide 50%of t he sat urat ion level in t he luminance at t he segment which t he ON signal is applied t o. Vt h2 :The volt age VO- P t hat should provide 50%of t he sat urat ion level in t he luminance at t he segment which t he OFF signal is applied t o.
VO-P
( B-2 ) VO-P / B 1 / ( fF A ) 1 / fF


DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 7/ 17
3.3.Definit ion of Viewing Angle and Opt imum Viewing Area * Point * shows t he point where cont rast rat io is measured. : q= 0, f= - * Driving condit ion : 1/ 16 Dut y, 1/ 5 Bias, VD=6.5V, fF=100Hz
90 135 45
f
q
90
180
10 20 30 40 50
(f = 0) f 180 0
q
225 270
315 270
* Area
shows t yp. CR2
3.4.Syst em Block Diagram
Temperature Chamber Rotation Table ( q,f ) Photometer #1980A WB
f
LCD Optical Fiber
q
Computer
Control Unit & Waveform Generator Halogen bulb
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 8/ 17
4.I/ O T er minal
4.1.Pin Assignment CN1 No. 1 2 Symbol A0 WR (E) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CS D7 D6 D5 D4 D3 D2 D1 D0 VDD VSS V5 V4 V3 V2 V1 VOUT VSS VDD P/ S IF RES H/ L H/ L H/ L H/ L H/ L H/ L H/ L H/ L H/ L H/ L H/ L H/ L Level H/ L H/ L Funct ion H : D0~D7 are display dat a. L : D0~D7 are a command. 80 family MPU : WR Signal Input L : Act ive
68 family MPU : Enable Clock Input Chip select signal. L : Act ive Dat a Bus Line Dat a Bus Line Dat a Bus Line Dat a Bus Line Dat a Bus Line / Non- connect ion at 4- bit operat ion Dat a Bus Line / Non- connect ion at 4- bit operat ion Dat a Bus Line / Non- connect ion at 4- bit operat ion Dat a Bus Line / Non- connect ion at 4- bit operat ion Supply Volt age + 3V Supply Volt age 0V (GND) Connect t o VDD and a capacit or of 0.1~4.7mF(Cf.chap.4.2) Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2) Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2) Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2) Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2) Supply Volt age (LCD Drive) Supply Volt age 0V ( GND) Supply Volt age + 3V H : Parallel Dat a Transfer, L : Serial Dat a Transfer Int erface Dat a Lengt h Select .H : 8- bit Parallel,L : 4- bit Parallel In case of a 68 series MPU,init ializat ion can be performed by changing RES . In case of an 80 series MPU,init ializat ion .
can be performed by changung
A reset operat ion is performed by edge sensing of t he RES signal. An interfase t ype for t he 68/ 80 seriees MPU is select ed by Input level aft er init ializat ion.
L : 68 series MPU interface. H : 80 series MPU interface.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 9/ 17
4.2.Example of Power Supply It is recommended t o apply a potent iomet er for t he cont rast adjust due t o t he t olerance of t he driving volt age and it s t emperat ure dependence.
VDD
VDD (+3V)
MODULE
VSS VR VSS C5 C4 C3 C2 C1
GND (0V)
VOUT (-7V)
V5 V4 V3 V2 V1
VR=10~20KW C1~C5:0.1~4.7m F
4.3.Block Diagram
DB7
~
8
DB0 RES IF P/S CS
COM 14
LCDP 16 Characters 2 Lines
SEG 80
Control LSI
WR
A0 VOUT V1~V5 VDD VSS
5
SED1233DGB
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 10/ 17
5.T est
No change on display and in operat ion under t he following t est condit ion. Condit ions: Unless otherwise specified, t est s will be conduct ed under t he following condit ion. Temperat ure: 205C Humidit y : 655% RH t est s will be not conduct ed under funct ioning st at e. Paramet er Condit ions Notes 1 2 3 2,3 2,3 2
No. 1 2 3 4 5 6
High Temperat ure Operat ing 50C2C, 96hrs (operat ion st at e) Low Temperat ure Operat ing High Temperat ure St orage Low Temperat ure St orage Damp Proof Test Heat Shock Test 0C2C, 96hrs (operat ion st at e) 70C2C, 96hrs - 20C2C, 96hrs 40C2C,90~95% RH, 96hrs - 25C (30min) (R) 25C (5min) (R) 70C (30min)
(R) 25C (5min) 5 cycles
7
Vibrat ion Test
Total fixed amplit ude : 1.5mm Vibrat ion Frequuency : 10~55HZ One cycle 60seconds t o 3direct ions of X,Y,Z for Each 15 minut es
4
Note 1 : It shhould be checked at t he act ual driving condit ion under t he high t emperat ure. Note 2 : No dew condensat ion t o be observed. Note 3 : The funct ion t est shall be conduct ed aft er 4 hours st orage at t he normal t emperat ure and humidit y aft er removed from t he t est chamber. Note 4 : Vibrat ion t est will be conduct ed t o t he product it self wit hout put t ing it in a cont ainer.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 11/ 17
6.Appear anc e St andar ds
6.1.Inspect ion condit ions The LCD shall be inspect ed under 40W whit e fluorescent light . The dist ance bet ween t he eyes and t he sample shall be more t han 30cm. All direct ions for inspect ing t he sample should be wit hin 45against perpendicular line.
45
6.2.Definit ion of applicable Zones
X
X
X
A Zone B Zone X C Zone X : Maximum Seal Line
A Zone : Act ive display area B Zone : Out of act ive display area ~ Maximum seal line C Zone : Rest part s A Zone + B Zone = Validit y viewing area
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 12/ 17
6.3.St andards No. 1 Paramet er Black and Whit e Spots, Foreign Subst ances Dimension (mm) D 0.1 0.1 < D 0.2 0.2 < D 0.3 0.3 < D D = ( Long + Short ) / 2 (2) Line Shape Zone X(mm) 2.0L 1.0L 1.0L Y(mm) 0.02W 0.03W 0.04W 0.05W 0.05X : Lengt h Y : Width
Total defect s shall not exceed 5. 2 Air Bubbles (bet ween glass & polarizer) Dimension (mm) D 0.15 0.15< D 0.3 0.3 < D 0.5 0.5 < D 1.0 * : Disregard Total defect s shall not exceed 3. Zone A * 2 1 0 Accept able Number B * 3 2 1 C * * * *
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 13/ 17
No. 3
Paramet er The Shape of Dot (1) Dot Shape (wit h Dent )
0.15
Crit eria
As per t he sket ch of left hand.
(2) Dot Shape (wit h Project ion)
Should not be connect ed t o next dot.
(3) Pin Hole
X
(X+Y) / 20.2mm
Y
(Less t han 0.1mm is no count ed.)
Total defect s shall not exceed 5. 4 5 Polarizer Scrat ches Dirt s Polarizer Not t o be conspicuous defect s. If t he st ains are removed easily from LCDP surface, t he module isnot defect ive. not 6 Color Variat ion Not t o be conspicuous defect s.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 14/ 17
7.Code Syst em of Pr oduc t ion L ot
The product ion lot of module is specified as follows.
Fact ory Number (Numeral) Fact ory Code (Alphabet ) Product ion Week (1~5) Product ion Mont h (1~9, X, Y, Z) Product ion Year (Lower 2 digit s)
8.Applying Pr ec aut ions
Please cont act us when quest ions and/ or new problems not specified in t his specificat ions arise.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 15/ 17
9.Pr ec aut ions Relat ing Pr oduc t Handling
The Following precaut ions will guide you in handling our product correct ly. 1) Liquid cryst al display devices 1. The liquid cryst al display device panel used in t he liquid cryst al display module is made of plat e glass. Avoid any st rong mechanical shock. Should t he glass break handle it wit h care 2. The polarizer adhering t o t he surface of t he LCD is made of a soft mat erial. Guard against scrat ching it . 2) Care of t he liquid cryst al display module against st at ic elect ricit y discharge. 1. When working wit h t he module, be sure t o ground your body and any elect rical equipment you may be using. We st rongly recommend t he use of ant i st at ic mat s ( made of rubber ), t o protect work t ables against t he hazards of elect rical shock. 2. Avoid t he use of work clot hing made of synt het ic fibers. We recommend cott on clot hing or other conduct ivit y- t reat ed fibers. 3. Slowly and carefully remove t he protect ive film from t he LCD module, since t his operat ion can generat e st at ic elect ricit y. 3) When t he LCD module alone must be st ored for long periods of t ime: 1. Protect t he modules from high t emperat ure and humidit y. 2. Keep t he modules out of direct sunlight or direct exposure t o ult raviolet rays. 3. Protect t he modules from excessive ext ernal forces. 4) Use t he module wit h a power supply t hat is equipped wit h an overcurrent protect or circuit , since t he module is not provided wit h t his protect ive feat ure. 5) Do not ingest t he LCD fluid it self should it leak out of a damaged LCD module. Should hands or clot hing come in cont act wit h LCD fluid, wash immediat ely wit h soap. 6) Conduct ivit y is not guarant eed for models t hat use met al holders where solder connect ions bet ween t he met al holder and t he PCB are not used. Please cont act us t o discuss appropriat e ways t o assure conduct ivit y. 7) For models which use CFL: 1. High volt age of 1000V or great er is applied t o t he CFL cable connect or area. Care should be t aken not t o t ouch connect ion areas t o avoid burns. 2. Protect CFL cables from rubbing against t he unit and t hus causing t he wire jacket t o become worn. 3.The use of CFLs for ext ended periods of t ime at low t emperat ures will significant ly short en t heir service life. 8) For models which use t ouch panels: 1.Do not st ack up modules since t hey can be damaged by component s on neighboring modules. 2.Do not place heavy object s on t op of t he product . This could cause glass breakage. 9) For models which use COG,TAB,or COF: 1.The mechanical st rengt h of t he product is low since t he IC chip faces out unprotect ed from t he rear. Be sure t o protect t he rear of t he IC chip from ext ernal forces. 2.Given t he fact t hat t he rear of t he IC chip is left exposed, in order t o protect t he unit from elect rical damage, avoid installat ion configurat ions in which t he rear of t he IC
DMC- 50747NF- AK (AK) No. 2001- 0124 OPTREX CORPORATION Page 16/ 17
chip runs t he risk of making any elect rical cont act . 10) Models which use flexible cable, heat seal, or TAB: 1.In order t o maintain reliabilit y, do not t ouch or hold by t he connect or area. 2.Avoid any bending, pulling, or other excessive force, which can result in broken connect ions.
10.War r ant y
This product has been manufact ured t o your company' s specificat ions as a part for use in your company' s general elect ronic product s. It is guarant eed t o perform according t o delivery specificat ions. For any other use apart from general elect ronic equipment , we cannot t ake responsibilit y if t he product is used in medical devices, nuclear power cont rol equipment , aerospace equipment , fire and securit y syst ems, or any other applicat ions in which t here is a direct risk t o human life and where ext remely high levels of reliabilit y are required. If t he product is t o be used in any of t he above applicat ions, we will need t o ent er into a separat e product liabilit y agreement . 1. We cannot accept responsibilit y for any defect , which may arise from addit ional manufact uring of t he product (including disassembly and reassembly), aft er product delivery. 2. We cannot accept responsibilit y for any defect , which may arise aft er t he applicat ion of st rong ext ernal force t o t he product . 3. We cannot accept responsibilit y for any defect , which may arise due t o t he applicat ion of st at ic elect ricit y aft er t he product has passed your company' s accept ance inspect ion procedures. 4. When t he product is in CFL models, CFL service life and bright ness will vary according t o t he performance of t he invert er used, leaks, et c. We cannot accept responsibilit y for product performance, reliabilit y, or defect , which may arise. 5. We cannot accept responsibilit y for int ellect ual propert y of a t hird part y, which may arise t hrough t he applicat ion of our product t o your assembly wit h except ion t o t hose issues relat ing direct ly t o t he st ruct ure or met hod of manufact uring of our product . 6. Opt rex will not be held responsible for any qualit y guarant ee issue for defect product s judged as Opt rex- origin longer t han 2 (t wo) years from Opt rex product ion or 1(one) year from Opt rex, Opt rex America, Opt rex Europe, Display LC delivery which ever comes lat er.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 17/ 17


▲Up To Search▲   

 
Price & Availability of DMC-50747NF-AK

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X